| Vibration pickup: |
|
| – Internal: |
Integrated piezoelectric acceleration |
| – External: |
Accepts a standard 100 mV/g constant current accelerometer |
| Temperature sensor: |
Internal infrared temperature sensor |
| Measurements: |
|
| – Velocity: |
Range: 0,7 to 65,0 mm/s (RMS) (0.04 to 3.60 in./s (equivalent Peak)), meets ISO 10816-3 |
| Frequency: 10 to 1 000 Hz, meets ISO 2954 |
| – Enveloped acceleration: |
Range: 0,2 to 50,0 gE |
| · Frequency: Similar to Band 3 (500 to 10 000 Hz) |
| – Temperature: |
Range: –20 to +200 °C (–5 to +390 °F) |
| Infrared temperature accuracy: 2 °C (4 °F) |
| Distance: Short range, maximum 10 cm (4 in.) from target |
| Operating temperature range: |
In use: –10 to +60 °C (15 to 140 °F) |
| While charging: 0 to 40 °C (30 to 105 °F) |
| Storage temperature: |
|
| – Less than one month: |
–20 to +45 °C (–5 to +115 °F) |
| – More than one month, but less than six months: |
–20 to +35 °C (–5 to +95 °F) |
| Humidity: |
95% relative humidity, non-condensing |
| Enclosure: |
IP 54 |
| Approvals: |
CE |
| Drop test: |
2 m (6.6 ft.) |
| Weight: |
125 g (4.4 oz.) |
| Dimensions: |
|
| – Length: |
200,0 mm (7.90 in.) |
| – Width: |
47,0 mm (1.85 in.) |
| – Height: |
25,4 mm (1.00 in.) |
| Battery life: |
10 hours before charging again ( 1 000 measurements) |
| – With external sensor: |
Up to 55% less battery life |
| Supported external sensor: |
Any standard accelerometer with 100 mV/g sensitivity constant current |
| External sensor power: |
24 V DC at 3,5 mA |
| Charger specifications: |
Universal AC/DC wall plug-in |
| Input: 90 to 264 V AC, 47 to 60 Hz |
| Output: 5 V DC regulated |
| 3 to 4 hours for a full charge |